Field fix / guidePLC / HMI Code & LogicVendor-agnostic (IEC 61131-3)Mixing Dosingindustrial-automation

Aquaculture System — PLC Control Template

Shared by TSIMEREZIVO Team · 4 Oct 2026 · 36 views

# Aquaculture System — Usage Guide ## Overview Aquaculture support template that supervises dissolved oxygen, temperature, pH, and feed dosing. It is intended for tank-based fish production or hatchery support systems. ## Commissioning 1. Verify DO, pH, and temperature probe calibration before enabling automatic actions 2. Test aerator and cooling outputs independently 3. Validate feed schedule timing and duration against species feeding plan --- ## Control Logic — Vendor-Agnostic Pseudocode # Aquaculture System — Logic ## Standards: IEC 61131-3 | ISA-5.1 | ISA-18.2 ## Scan Rate: 500ms | Pattern: dissolved oxygen, feed dosing, temperature and pH supervision ``` ROUTINE: AquacultureSystem SCAN_RATE: 500ms // SECTION 1 — CORE ENVIRONMENTAL CONTROL IF DO_PV <= DO_LOW_SP THEN AERATOR_CMD := TRUE END_IF IF DO_PV >= DO_HIGH_SP THEN AERATOR_CMD := FALSE END_IF IF TEMP_PV >= TEMP_HIGH_SP THEN COOLING_CMD := TRUE END_IF IF TEMP_PV <= TEMP_LOW_SP THEN COOLING_CMD := FALSE END_IF // SECTION 2 — FEED DOSING IF FEED_TIME_MATCH AND AUTO_MODE THEN FEEDER_CMD := TRUE FEED_TMR := FEED_TMR + 1 IF FEED_TMR >= FEED_DURATION_TICKS THEN FEEDER_CMD := FALSE FEED_TMR := 0 FEED_COUNT := FEED_COUNT + 1 END_IF END_IF // SECTION 3 — WATER QUALITY ALARMS IF DO_PV <= DO_CRIT_SP THEN SET_ALARM(ALM_DO_CRIT, CRITICAL) END_IF IF PH_PV <= PH_LOW_SP OR PH_PV >= PH_HIGH_SP THEN SET_ALARM(ALM_PH_OUT, HIGH) END_IF IF TEMP_PV >= TEMP_HH_SP THEN SET_ALARM(ALM_TEMP_HH, HIGH) END_IF // SECTION 4 — HMI HMI_DO := DO_PV HMI_PH := PH_PV HMI_TEMP := TEMP_PV HMI_FEED_COUNT := FEED_COUNT END_ROUTINE ``` --- ## Tag List ```csv Tag Name,Description,Data Type,Direction,Engineering Unit,Range Min,Range Max,Default Value,Address AUTO_MODE,Automatic Mode Enable,BOOL,input,,,,TRUE, DO_PV,Dissolved Oxygen Process Value,REAL,input,mg/L,0,20,7,AI:0:0.0 PH_PV,pH Process Value,REAL,input,pH,0,14,7,AI:0:0.1 TEMP_PV,Water Temperature,REAL,input,°C,0,50,24,AI:0:0.2 DO_LOW_SP,Dissolved Oxygen Start Aeration Setpoint,REAL,internal,mg/L,0,20,5, DO_HIGH_SP,Dissolved Oxygen Stop Aeration Setpoint,REAL,internal,mg/L,0,20,7, DO_CRIT_SP,Critical Dissolved Oxygen Setpoint,REAL,internal,mg/L,0,20,3, PH_LOW_SP,Low pH Setpoint,REAL,internal,pH,0,14,6.5, PH_HIGH_SP,High pH Setpoint,REAL,internal,pH,0,14,8.5, TEMP_LOW_SP,Low Temperature Cooling Reset,REAL,internal,°C,0,50,24, TEMP_HIGH_SP,High Temperature Cooling Start,REAL,internal,°C,0,50,28, TEMP_HH_SP,High-High Temperature Alarm,REAL,internal,°C,0,50,32, FEED_TIME_MATCH,Feed Schedule Match,BOOL,input,,,,FALSE, FEEDER_CMD,Feed Doser Command,BOOL,output,,,,FALSE,DO:1:0.0 AERATOR_CMD,Aerator Command,BOOL,output,,,,FALSE,DO:1:0.1 COOLING_CMD,Cooling Valve/Fan Command,BOOL,output,,,,FALSE,DO:1:0.2 FEED_TMR,Feed Duration Timer,INT,internal,,0,10000,0, FEED_DURATION_TICKS,Feed Duration (500ms ticks),INT,internal,,0,10000,20, FEED_COUNT,Completed Feed Events,DINT,internal,,0,999999,0, ALM_DO_CRIT,Critical Low Dissolved Oxygen Alarm,BOOL,calculated,,,,FALSE, ALM_PH_OUT,pH Out of Range Alarm,BOOL,calculated,,,,FALSE, ALM_TEMP_HH,High Temperature Alarm,BOOL,calculated,,,,FALSE, HMI_DO,HMI: Dissolved Oxygen,REAL,output,mg/L,0,20,7, HMI_PH,HMI: pH,REAL,output,pH,0,14,7, HMI_TEMP,HMI: Temperature,REAL,output,°C,0,50,24, HMI_FEED_COUNT,HMI: Feed Count,DINT,output,,0,999999,0, ``` --- ## Alarm Matrix ```csv Alarm Tag,Condition,Setpoint,Priority,Type,Response,Delay,Auto Acknowledge ALM_DO_CRIT,DO_PV <= DO_CRIT_SP,3 mg/L,critical,process,Critical oxygen deficiency. Force aeration and escalate immediately.,0s,No ALM_PH_OUT,PH_PV outside PH_LOW_SP..PH_HIGH_SP,6.5-8.5,high,process,pH outside acceptable range. Check dosing chemistry and bio-load.,5s,No ALM_TEMP_HH,TEMP_PV >= TEMP_HH_SP,32°C,high,process,Water temperature high. Increase cooling and reduce stocking stress.,5s,No ```

More like this

Rate, comment, and get full access

Members can download files, rate contributions, and discuss fixes with the engineers who posted them — free.

Join the library