Multi Level Parking — PLC Control Template

Shared by TSIMEREZIVO Team · 4 Oct 2026 · 46 views

# Multi Level Parking — Usage Guide ## Overview Parking structure guidance template that computes available spaces per level and recommends the next level with availability. ## Commissioning 1. Verify occupancy sources for each level 2. Validate guidance priority order matches site signage strategy 3. Confirm full condition is declared only when all levels are at capacity --- ## Control Logic — Vendor-Agnostic Pseudocode # Multi Level Parking — Logic ## Standards: IEC 61131-3 ## Scan Rate: 100ms | Pattern: floor-by-floor capacity supervision ``` ROUTINE: MultiLevelParking SCAN_RATE: 100ms // SECTION 1 — AVAILABILITY L1_AVAILABLE := L1_CAPACITY - L1_OCCUPIED L2_AVAILABLE := L2_CAPACITY - L2_OCCUPIED L3_AVAILABLE := L3_CAPACITY - L3_OCCUPIED TOTAL_AVAILABLE := L1_AVAILABLE + L2_AVAILABLE + L3_AVAILABLE // SECTION 2 — GUIDANCE SELECTION IF L1_AVAILABLE > 0 THEN GUIDE_LEVEL := 1 ELSIF L2_AVAILABLE > 0 THEN GUIDE_LEVEL := 2 ELSIF L3_AVAILABLE > 0 THEN GUIDE_LEVEL := 3 ELSE GUIDE_LEVEL := 0 END_IF // SECTION 3 — ALARMS IF TOTAL_AVAILABLE <= 0 THEN SET_ALARM(ALM_PARKING_FULL, HIGH) END_IF // SECTION 4 — HMI HMI_TOTAL_AVAILABLE := TOTAL_AVAILABLE HMI_GUIDE_LEVEL := GUIDE_LEVEL END_ROUTINE ``` --- ## Tag List ```csv Tag Name,Description,Data Type,Direction,Engineering Unit,Range Min,Range Max,Default Value,Address L1_OCCUPIED,Level 1 Occupied Spaces,INT,input,,0,10000,0, L2_OCCUPIED,Level 2 Occupied Spaces,INT,input,,0,10000,0, L3_OCCUPIED,Level 3 Occupied Spaces,INT,input,,0,10000,0, L1_CAPACITY,Level 1 Capacity,INT,internal,,0,10000,100, L2_CAPACITY,Level 2 Capacity,INT,internal,,0,10000,100, L3_CAPACITY,Level 3 Capacity,INT,internal,,0,10000,100, L1_AVAILABLE,Level 1 Available Spaces,INT,calculated,,0,10000,0, L2_AVAILABLE,Level 2 Available Spaces,INT,calculated,,0,10000,0, L3_AVAILABLE,Level 3 Available Spaces,INT,calculated,,0,10000,0, TOTAL_AVAILABLE,Total Available Spaces,INT,calculated,,0,30000,0, GUIDE_LEVEL,Recommended Level to Guide Drivers,INT,calculated,,0,3,0, ALM_PARKING_FULL,Parking Full Alarm,BOOL,calculated,,,,FALSE, HMI_TOTAL_AVAILABLE,HMI: Total Available Spaces,INT,output,,0,30000,0, HMI_GUIDE_LEVEL,HMI: Guide Level,INT,output,,0,3,0, ``` --- ## Alarm Matrix ```csv Alarm Tag,Condition,Setpoint,Priority,Type,Response,Delay,Auto Acknowledge ALM_PARKING_FULL,TOTAL_AVAILABLE <= 0,0 spaces,high,process,Parking structure full. Entry guidance should redirect drivers away.,0s,No ```

More like this

Rate, comment, and get full access

Members can download files, rate contributions, and discuss fixes with the engineers who posted them — free.

Join the library