Gravimetric Dosing — PLC Control Template

Shared by TSIMEREZIVO Team · 4 Oct 2026 · 37 views

# Gravimetric Dosing — Usage Guide ## Overview Loss-in-weight feeder control template that trims feeder speed to meet a mass-flow setpoint while pausing during refill events. ## Commissioning 1. Verify loadcell stability and zero tracking 2. Tune `GAIN` from small to moderate values to avoid hunting 3. Confirm refill inhibit prevents false flow correction during top-up --- ## Control Logic — Vendor-Agnostic Pseudocode # Gravimetric Dosing — Logic ## Standards: IEC 61131-3 | ISA-5.1 | ISA-18.2 ## Scan Rate: 50ms | Pattern: loss-in-weight feeder control ``` ROUTINE: GravimetricDosing SCAN_RATE: 50ms // SECTION 1 — WEIGHT RATE CALCULATION LOSS_RATE := PREV_WEIGHT - HOPPER_WEIGHT PREV_WEIGHT := HOPPER_WEIGHT INST_FLOW_KGS := LOSS_RATE / 0.05 // SECTION 2 — SPEED TRIM ERROR := FLOW_SP_KGS - INST_FLOW_KGS FEEDER_SPEED_CMD := CLAMP(FEEDER_SPEED_CMD + ERROR * GAIN, 0.0, 100.0) // SECTION 3 — REFILL INHIBIT IF REFILL_ACTIVE THEN FEEDER_ENABLE := FALSE SET_ALARM(ALM_REFILL_ACTIVE, LOW) ELSE FEEDER_ENABLE := AUTO_MODE AND NOT ESTOP_ACTIVE END_IF // SECTION 4 — LOW MATERIAL ALARM IF HOPPER_WEIGHT <= LOW_WEIGHT_SP THEN SET_ALARM(ALM_LOW_HOPPER, HIGH) END_IF IF ESTOP_ACTIVE THEN SET_ALARM(ALM_ESTOP, CRITICAL) END_IF // SECTION 5 — HMI OUTPUTS HMI_FLOW := INST_FLOW_KGS HMI_SPEED := FEEDER_SPEED_CMD HMI_WEIGHT := HOPPER_WEIGHT END_ROUTINE ``` --- ## Tag List ```csv Tag Name,Description,Data Type,Direction,Engineering Unit,Range Min,Range Max,Default Value,Address AUTO_MODE,Automatic Mode Enable,BOOL,input,,,,TRUE, ESTOP_ACTIVE,E-Stop Active,BOOL,input,,,,FALSE,DI:0:0.0 REFILL_ACTIVE,Refill Sequence Active,BOOL,input,,,,FALSE,DI:0:0.1 HOPPER_WEIGHT,Hopper Weight,REAL,input,kg,0,500,0,AI:0:0.0 PREV_WEIGHT,Previous Hopper Weight,REAL,internal,kg,0,500,0, LOSS_RATE,Weight Loss Per Scan,REAL,calculated,kg,-50,50,0, INST_FLOW_KGS,Instantaneous Flow,REAL,calculated,kg/s,0,50,0, FLOW_SP_KGS,Flow Setpoint,REAL,input,kg/s,0,50,1.5, ERROR,Flow Error,REAL,calculated,kg/s,-50,50,0, GAIN,Speed Trim Gain,REAL,internal,,0,100,5, FEEDER_SPEED_CMD,Feeder Speed Command,REAL,output,%,0,100,0, FEEDER_ENABLE,Feeder Enable,BOOL,output,,,,FALSE,DO:1:0.0 LOW_WEIGHT_SP,Low Hopper Weight Setpoint,REAL,internal,kg,0,500,25, ALM_REFILL_ACTIVE,Refill Active Alarm,BOOL,calculated,,,,FALSE, ALM_LOW_HOPPER,Low Hopper Weight Alarm,BOOL,calculated,,,,FALSE, ALM_ESTOP,E-Stop Alarm,BOOL,calculated,,,,FALSE, HMI_FLOW,HMI: Instantaneous Flow,REAL,output,kg/s,0,50,0, HMI_SPEED,HMI: Feeder Speed,REAL,output,%,0,100,0, HMI_WEIGHT,HMI: Hopper Weight,REAL,output,kg,0,500,0, ``` --- ## Alarm Matrix ```csv Alarm Tag,Condition,Setpoint,Priority,Type,Response,Delay,Auto Acknowledge ALM_ESTOP,ESTOP_ACTIVE = TRUE,N/A,critical,safety,Emergency stop active. Feeder disabled.,0s,No ALM_LOW_HOPPER,HOPPER_WEIGHT <= LOW_WEIGHT_SP,25kg,high,process,Low hopper inventory. Schedule refill to maintain dosing continuity.,2s,No ALM_REFILL_ACTIVE,REFILL_ACTIVE = TRUE,N/A,low,process,Refill active. Dosing paused until stable weighing resumes.,0s,Yes ```

More like this

Rate, comment, and get full access

Members can download files, rate contributions, and discuss fixes with the engineers who posted them — free.

Join the library