Auto Car Washing — PLC Control Template
Shared by TSIMEREZIVO Team · 4 Oct 2026 · 46 views
# Auto Car Washing — Usage Guide
## Overview
Timed car wash sequence with soap, rinse, and dry stages.
## Commissioning
1. Verify vehicle position detection before allowing automatic cycle start
2. Tune each stage duration for site equipment and water pressure
3. Test E-stop drop-out of all outputs
---
## Control Logic — Vendor-Agnostic Pseudocode
# Auto Car Washing — Logic
## Standards: IEC 61131-3 | ISA-88-style sequence
## Scan Rate: 100ms | Pattern: wash-rinse-dry sequence
```
ROUTINE: AutoCarWashing
SCAN_RATE: 100ms
CASE SEQ_STATE OF
0: IF START_CMD AND VEHICLE_IN_POSITION THEN SEQ_STATE := 1 END_IF
1: SOAP_CMD := TRUE; TMR := TMR + 1; IF TMR >= SOAP_TICKS THEN SOAP_CMD := FALSE; TMR := 0; SEQ_STATE := 2 END_IF
2: RINSE_CMD := TRUE; TMR := TMR + 1; IF TMR >= RINSE_TICKS THEN RINSE_CMD := FALSE; TMR := 0; SEQ_STATE := 3 END_IF
3: DRY_CMD := TRUE; TMR := TMR + 1; IF TMR >= DRY_TICKS THEN DRY_CMD := FALSE; TMR := 0; SEQ_STATE := 4 END_IF
4: COMPLETE := TRUE; IF ACK_CMD THEN COMPLETE := FALSE; SEQ_STATE := 0 END_IF
END_CASE
IF ESTOP_ACTIVE THEN SOAP_CMD := FALSE; RINSE_CMD := FALSE; DRY_CMD := FALSE; SET_ALARM(ALM_ESTOP, CRITICAL) END_IF
HMI_SEQ_STATE := SEQ_STATE
END_ROUTINE
```
---
## Tag List
```csv
Tag Name,Description,Data Type,Direction,Engineering Unit,Range Min,Range Max,Default Value,Address
START_CMD,Wash Start Command,BOOL,input,,,,FALSE,
ACK_CMD,Sequence Complete Acknowledge,BOOL,input,,,,FALSE,
VEHICLE_IN_POSITION,Vehicle in Wash Position,BOOL,input,,,,FALSE,DI:0:0.0
ESTOP_ACTIVE,E-Stop Active,BOOL,input,,,,FALSE,DI:0:0.1
SEQ_STATE,Wash Sequence State,INT,internal,,0,4,0,
TMR,Sequence Step Timer,INT,internal,,0,100000,0,
SOAP_TICKS,Soap Step Duration,INT,internal,,0,100000,100,
RINSE_TICKS,Rinse Step Duration,INT,internal,,0,100000,100,
DRY_TICKS,Dry Step Duration,INT,internal,,0,100000,150,
SOAP_CMD,Soap Command,BOOL,output,,,,FALSE,DO:1:0.0
RINSE_CMD,Rinse Command,BOOL,output,,,,FALSE,DO:1:0.1
DRY_CMD,Dry Command,BOOL,output,,,,FALSE,DO:1:0.2
COMPLETE,Sequence Complete,BOOL,internal,,,,FALSE,
ALM_ESTOP,E-Stop Alarm,BOOL,calculated,,,,FALSE,
HMI_SEQ_STATE,HMI: Sequence State,INT,output,,0,4,0,
```
---
## Alarm Matrix
```csv
Alarm Tag,Condition,Setpoint,Priority,Type,Response,Delay,Auto Acknowledge
ALM_ESTOP,ESTOP_ACTIVE = TRUE,N/A,critical,safety,Emergency stop active. Wash sequence halted immediately.,0s,No
```