3 Floor Parking — PLC Control Template
Shared by TSIMEREZIVO Team · 4 Oct 2026 · 35 views
# 3 Floor Parking — Usage Guide
## Overview
Three-floor parking guidance template that drives individual floor availability signs.
## Commissioning
1. Verify each floor occupancy source
2. Confirm sign outputs change correctly with occupancy thresholds
3. Validate full condition blocks further vehicle admission
---
## Control Logic — Vendor-Agnostic Pseudocode
# 3 Floor Parking — Logic
## Standards: IEC 61131-3
## Scan Rate: 100ms | Pattern: three-floor occupancy guidance
```
ROUTINE: ThreeFloorParking
SCAN_RATE: 100ms
F1_FREE := F1_CAPACITY - F1_OCCUPIED
F2_FREE := F2_CAPACITY - F2_OCCUPIED
F3_FREE := F3_CAPACITY - F3_OCCUPIED
IF F1_FREE > 0 THEN SIGN_F1 := TRUE ELSE SIGN_F1 := FALSE END_IF
IF F2_FREE > 0 THEN SIGN_F2 := TRUE ELSE SIGN_F2 := FALSE END_IF
IF F3_FREE > 0 THEN SIGN_F3 := TRUE ELSE SIGN_F3 := FALSE END_IF
FULL := (F1_FREE <= 0) AND (F2_FREE <= 0) AND (F3_FREE <= 0)
IF FULL THEN SET_ALARM(ALM_FULL, HIGH) END_IF
HMI_F1_FREE := F1_FREE
HMI_F2_FREE := F2_FREE
HMI_F3_FREE := F3_FREE
END_ROUTINE
```
---
## Tag List
```csv
Tag Name,Description,Data Type,Direction,Engineering Unit,Range Min,Range Max,Default Value,Address
F1_OCCUPIED,Floor 1 Occupied,INT,input,,0,10000,0,
F2_OCCUPIED,Floor 2 Occupied,INT,input,,0,10000,0,
F3_OCCUPIED,Floor 3 Occupied,INT,input,,0,10000,0,
F1_CAPACITY,Floor 1 Capacity,INT,internal,,0,10000,50,
F2_CAPACITY,Floor 2 Capacity,INT,internal,,0,10000,50,
F3_CAPACITY,Floor 3 Capacity,INT,internal,,0,10000,50,
F1_FREE,Floor 1 Free Spaces,INT,calculated,,0,10000,0,
F2_FREE,Floor 2 Free Spaces,INT,calculated,,0,10000,0,
F3_FREE,Floor 3 Free Spaces,INT,calculated,,0,10000,0,
SIGN_F1,Floor 1 Available Sign,BOOL,output,,,,FALSE,DO:1:0.0
SIGN_F2,Floor 2 Available Sign,BOOL,output,,,,FALSE,DO:1:0.1
SIGN_F3,Floor 3 Available Sign,BOOL,output,,,,FALSE,DO:1:0.2
FULL,All Floors Full,BOOL,calculated,,,,FALSE,
ALM_FULL,Parking Full Alarm,BOOL,calculated,,,,FALSE,
HMI_F1_FREE,HMI: Floor 1 Free Spaces,INT,output,,0,10000,0,
HMI_F2_FREE,HMI: Floor 2 Free Spaces,INT,output,,0,10000,0,
HMI_F3_FREE,HMI: Floor 3 Free Spaces,INT,output,,0,10000,0,
```
---
## Alarm Matrix
```csv
Alarm Tag,Condition,Setpoint,Priority,Type,Response,Delay,Auto Acknowledge
ALM_FULL,FULL = TRUE,0 spaces,high,process,All floors full. Entry guidance should stop admitting vehicles.,0s,No
```