Field fix / guidePLC / HMI Code & LogicVendor-agnostic (IEC 61131-3)Tank Liquidindustrial-automation

Dam Gate 5 Alarm Levels — PLC Control Template

Shared by TSIMEREZIVO Team · 4 Oct 2026 · 37 views

# Dam Gate 5 Alarm Levels — Usage Guide ## Overview Flood-management template with five escalating alarm levels and corresponding gate position commands. Designed for reservoir outlet gates, spillway control, and storm-water retention systems where simple, deterministic staged response is preferred. ## Stage Map | Stage | Threshold | Gate Command | Meaning | |------|-----------|--------------|---------| | 0 | below `SP_STAGE1` | 0% | Normal | | 1 | `SP_STAGE1` | 20% | Advisory | | 2 | `SP_STAGE2` | 40% | Flood watch | | 3 | `SP_STAGE3` | 60% | Flood warning | | 4 | `SP_STAGE4` | 80% | Severe flood warning | | 5 | `SP_STAGE5` | 100% | Emergency spill | ## Commissioning 1. Verify dam level scaling and sensor redundancy policy 2. Force each stage threshold and confirm matching gate command 3. Check actuator travel time and confirm 0 to 100% command range mapping 4. Review downstream hydraulic capacity before enabling AUTO mode --- ## Control Logic — Vendor-Agnostic Pseudocode # Dam Gate 5 Alarm Levels — Logic ## Standards: IEC 61131-3 | ISA-5.1 | ISA-18.2 ## Scan Rate: 250ms | Pattern: Flood management with 5-stage gate opening ``` ROUTINE: DamGateFiveAlarmLevels SCAN_RATE: 250ms // SECTION 1 — LEVEL MEASUREMENT LT001_MA := SCALE(LT001_RAW, 0, 27648, 4.0, 20.0) LT001_VALID := (LT001_MA >= 3.8) AND (LT001_MA <= 20.5) IF LT001_VALID THEN LEVEL_PV := SCALE(LT001_MA, 4.0, 20.0, 0.0, 100.0) LEVEL_LAST_GOOD := LEVEL_PV ELSE LEVEL_PV := LEVEL_LAST_GOOD SET_ALARM(ALM_LEVEL_SENSOR_FAIL, HIGH) END_IF // SECTION 2 — FIVE-LEVEL FLOOD ALARM STAGING IF LEVEL_PV >= SP_STAGE5 THEN GATE_STAGE := 5 ELSIF LEVEL_PV >= SP_STAGE4 THEN GATE_STAGE := 4 ELSIF LEVEL_PV >= SP_STAGE3 THEN GATE_STAGE := 3 ELSIF LEVEL_PV >= SP_STAGE2 THEN GATE_STAGE := 2 ELSIF LEVEL_PV >= SP_STAGE1 THEN GATE_STAGE := 1 ELSE GATE_STAGE := 0 END_IF // SECTION 3 — GATE POSITION COMMANDS CASE MODE_SELECTOR OF 0: // OFF GATE_CMD := 0.0 1: // MANUAL GATE_CMD := MAN_GATE_CMD 2: // AUTO CASE GATE_STAGE OF 0: GATE_CMD := 0.0 1: GATE_CMD := 20.0 2: GATE_CMD := 40.0 3: GATE_CMD := 60.0 4: GATE_CMD := 80.0 5: GATE_CMD := 100.0 END_CASE END_CASE // SECTION 4 — FLOOD ALARMS IF GATE_STAGE >= 1 THEN SET_ALARM(ALM_STAGE1, LOW) END_IF IF GATE_STAGE >= 2 THEN SET_ALARM(ALM_STAGE2, MEDIUM) END_IF IF GATE_STAGE >= 3 THEN SET_ALARM(ALM_STAGE3, HIGH) END_IF IF GATE_STAGE >= 4 THEN SET_ALARM(ALM_STAGE4, HIGH) END_IF IF GATE_STAGE >= 5 THEN SET_ALARM(ALM_STAGE5, CRITICAL) END_IF // SECTION 5 — HMI OUTPUTS HMI_LEVEL_PV := LEVEL_PV HMI_GATE_STAGE := GATE_STAGE HMI_GATE_CMD := GATE_CMD HMI_MODE := MODE_SELECTOR END_ROUTINE ``` --- ## Tag List ```csv Tag Name,Description,Data Type,Direction,Engineering Unit,Range Min,Range Max,Default Value,Address LT001_RAW,Dam Level Transmitter Raw ADC,INT,input,,0,27648,,AI:0:0.0 LT001_MA,Dam Level mA,REAL,calculated,mA,3.8,20.5,, LT001_VALID,Dam Level Transmitter Healthy,BOOL,calculated,,,,TRUE, LEVEL_PV,Dam Level Process Value,REAL,calculated,%,0,100,, LEVEL_LAST_GOOD,Last Good Dam Level,REAL,internal,%,0,100,50, MODE_SELECTOR,Operating Mode (0=OFF 1=MAN 2=AUTO),INT,input,,0,2,2, MAN_GATE_CMD,Manual Gate Position Command,REAL,input,%,0,100,0, GATE_STAGE,Active Flood Stage,INT,calculated,,0,5,0, GATE_CMD,Gate Position Command,REAL,output,%,0,100,0, SP_STAGE1,Stage 1 Flood Threshold,REAL,internal,%,0,100,60, SP_STAGE2,Stage 2 Flood Threshold,REAL,internal,%,0,100,70, SP_STAGE3,Stage 3 Flood Threshold,REAL,internal,%,0,100,80, SP_STAGE4,Stage 4 Flood Threshold,REAL,internal,%,0,100,90, SP_STAGE5,Stage 5 Flood Threshold,REAL,internal,%,0,100,97, ALM_LEVEL_SENSOR_FAIL,Dam Level Sensor Failure,BOOL,calculated,,,,FALSE, ALM_STAGE1,Stage 1 Flood Advisory,BOOL,calculated,,,,FALSE, ALM_STAGE2,Stage 2 Flood Watch,BOOL,calculated,,,,FALSE, ALM_STAGE3,Stage 3 Flood Warning,BOOL,calculated,,,,FALSE, ALM_STAGE4,Stage 4 Severe Flood Warning,BOOL,calculated,,,,FALSE, ALM_STAGE5,Stage 5 Emergency Spill Condition,BOOL,calculated,,,,FALSE, HMI_LEVEL_PV,HMI: Dam Level PV,REAL,output,%,0,100,, HMI_GATE_STAGE,HMI: Flood Stage,INT,output,,0,5,0, HMI_GATE_CMD,HMI: Gate Command,REAL,output,%,0,100,0, HMI_MODE,HMI: Operating Mode,INT,output,,0,2,2, ``` --- ## Alarm Matrix ```csv Alarm Tag,Condition,Setpoint,Priority,Type,Response,Delay,Auto Acknowledge ALM_LEVEL_SENSOR_FAIL,LT001_VALID = FALSE,wire-break,high,equipment,Level transmitter fault. Verify redundant gauging before operating gates automatically.,5s,No ALM_STAGE1,LEVEL_PV >= SP_STAGE1,60%,low,process,Stage 1 advisory. Prepare operators and inspect outflow channel.,10s,Yes ALM_STAGE2,LEVEL_PV >= SP_STAGE2,70%,medium,process,Stage 2 flood watch. Increase supervision and confirm gate availability.,5s,No ALM_STAGE3,LEVEL_PV >= SP_STAGE3,80%,high,process,Stage 3 flood warning. Confirm gate response and downstream evacuation plans.,3s,No ALM_STAGE4,LEVEL_PV >= SP_STAGE4,90%,high,process,Stage 4 severe flood condition. Maximum response readiness required.,1s,No ALM_STAGE5,LEVEL_PV >= SP_STAGE5,97%,critical,safety,Emergency spill condition. Command full gate opening and escalate immediately.,0s,No ```

More like this

Rate, comment, and get full access

Members can download files, rate contributions, and discuss fixes with the engineers who posted them — free.

Join the library