Engineering Library
Procedures, PLC and HMI code, drawings, and field-proven fixes shared by working controls and instrumentation engineers. Community contributions publish immediately and can be flagged for review. Membership is free — sign in to download, rate, and contribute.
126 published contributions
- Read more
Water Recycling Circuit & Density Balance — Control Design
Mining operations recycle water from thickener overflow back to upstream processes crusher, mill to conserve water and recover valuable solids from clarified water. However, recycled water carries suspended fines and rea…
TSIMEREZIVO Team · 33 views · 0 downloads
- Read more
Thickener Rake Torque & Underflow Clarity — Control Design
A thickener settling tank, 20–50 m diameter allows coarse solids to settle under gravity while water overflows as clarified product. A rotating rake mechanism slowly scrapes settled solids toward a central pump cone unde…
TSIMEREZIVO Team · 38 views · 0 downloads
- Read more
Flotation Cell Pulp Density & Air Control — Control Design
Froth flotation cells separate valuable minerals sulfides, oxides from gangue worthless rock by floating mineral particles to the surface and collecting froth overflow. Cell performance depends critically on maintaining …
TSIMEREZIVO Team · 35 views · 0 downloads
- Read more
Injection Mold Cavity Temperature Control — Control Design
Regulate injection mold cavity temperature via circulating heating/cooling water and proportional control valves. Critical for part dimensional stability, surface quality, and cycle time optimization in injection molding…
TSIMEREZIVO Team · 36 views · 0 downloads
- Read more
Batch Reactor Temperature Control — Control Design
Multi stage reaction vessel temperature regulation via jacket heating and cooling water circulation. Typical applications include pharmaceutical synthesis, chemical polymerization, food processing, cosmetics blending.
TSIMEREZIVO Team · 40 views · 0 downloads
- Read more
Dual Equipment Switchover (Automatic Failover) — Control Design
Switch load automatically from Primary → Secondary motor if Primary fails OR Primary demand exceeds capacity.
TSIMEREZIVO Team · 37 views · 0 downloads
- Read more
Emergency Shutdown (E-Stop) Logic — Control Design
Implement a hardwired emergency stop circuit that cuts power to all dangerous motors/actuators
TSIMEREZIVO Team · 46 views · 0 downloads
- Read more
Flow Control Loop (PID-Based) — Control Design
Maintain constant flow rate via proportional valve position or pump speed modulation. Independent of downstream pressure variations.
TSIMEREZIVO Team · 46 views · 0 downloads
- Read more
Pump Control (Single — On/Off with Protection) — Control Design
Start/stop a single electric motor pump with automatic overload protection, dry run prevention, and fault reporting.
TSIMEREZIVO Team · 39 views · 0 downloads
- Read more
Variable Frequency Drive (VFD) Motor Control — Control Design
Modulate AC motor speed via frequency control. Enables energy savings, process precision, and soft start capability.
TSIMEREZIVO Team · 40 views · 0 downloads
- Read more
Pump Control (Lead/Lag - Duty Cycling) — Control Design
Two identical pumps sharing duty load. Automatically alternates every 24 hours configurable to equalize wear and extend equipment life.
TSIMEREZIVO Team · 50 views · 0 downloads
- Read more
Single Tank Level Control — Control Design
Simple level control for a single tank with pump or valve control. The most fundamental control loop in industrial automation.
TSIMEREZIVO Team · 38 views · 0 downloads
- Read more
HVAC Control — AHU and Chiller Plant — Control Design
Building Management System BMS control of an Air Handling Unit AHU and chilled water plant serving a commercial or industrial facility. Covers supply air temperature, mixed air economizer, variable volume supply air, and…
TSIMEREZIVO Team · 46 views · 0 downloads
- Read more
Instrument Hook-Up Detail Template
Standard installation detail — one per instrument type per service class.
TSIMEREZIVO Team · 44 views · 0 downloads
- Read more
Vehicle Washing — PLC Control Template
Simple vehicle triggered wash spray control for wheel washes or spray arches.
TSIMEREZIVO Team · 36 views · 0 downloads
- Read more
Auto Car Washing — PLC Control Template
Timed car wash sequence with soap, rinse, and dry stages.
TSIMEREZIVO Team · 48 views · 0 downloads
- Read more
Tank To Tank Transfer — PLC Control Template
Metered transfer between two tanks with permissive gate, volume accumulation, source/destination level cutoffs, and timeout protection. Suitable for: raw material transfers, product blending feeds, CIP chemical dosing ta…
TSIMEREZIVO Team · 43 views · 0 downloads
- Read more
Liquid Temperature PID — PLC Control Template
PID temperature control with multi sensor averaging, split range heat/cool valve output, anti windup, derivative on PV no setpoint kick , overtemperature safety trip SIL1 , and ISA 18.2 alarm hierarchy.
TSIMEREZIVO Team · 34 views · 0 downloads
- Read more
Fill Drain Logic — PLC Control Template
Multi mode tank control OFF / MANUAL / AUTO FILL / AUTO DRAIN / BATCH SEQUENCE with dual valve discrepancy monitoring, ISA 88 sequence state machine, fill/drain timeout, and ISA 18.2 alarm hierarchy. Suitable for: proces…
TSIMEREZIVO Team · 38 views · 0 downloads
- Read more
Dam Gate 5 Alarm Levels — PLC Control Template
Flood management template with five escalating alarm levels and corresponding gate position commands. Designed for reservoir outlet gates, spillway control, and storm water retention systems where simple, deterministic s…
TSIMEREZIVO Team · 37 views · 0 downloads
- Read more
Auto Water Refill — PLC Control Template
Simple on/off solenoid valve refill control. Starts filling when level drops to SP_START , stops when it reaches SP_STOP . Includes timeout guard, supply fault detection, and HH safety override.
TSIMEREZIVO Team · 101 views · 0 downloads
- Read more
Water Level Pump Control — PLC Control Template
Hysteresis band level control with 4 tier ISA 18.2 alarm hierarchy, 3 point median filtering, wire break detection, leak rate monitoring, and manual/auto mode. Suitable for raw water tanks, buffer tanks, sump wells, cond…
TSIMEREZIVO Team · 98 views · 0 downloads
- Read more
Priority Liquid Level — PLC Control Template
3 stage cascaded priority pump control with redundant transmitter selection, runtime equalised pump assignment, hysteresis confirmed staging, and ISA 18.2 alarm hierarchy. Designed for high demand applications: municipal…
TSIMEREZIVO Team · 39 views · 0 downloads
- Read more
Latching Interlock Pump — PLC Control Template
This template implements production grade pump motor control with full IEC 61131 3 seal in latch, 7 condition permissive interlock gate, manual/auto/off mode, hard reset fault latch, star delta soft start sequencing, run…
TSIMEREZIVO Team · 50 views · 0 downloads
Worked on a project? Share what you learned.
Upload procedures, code, drawings — or post the fix that took you a day to find. Your experience is the library.
Create a free account